We got a wedding gun.
A long-standing interest in firearms resurfaces with a new piece from a family wedding, alongside reflections on collecting in the author's twenties and thirties.
Long-running personal blog from Chris Mapp: snack-food tastings, retro action figures, building blocks, fishing on the Chesapeake Bay, and the occasional pop-culture reflection.
A long-standing interest in firearms resurfaces with a new piece from a family wedding, alongside reflections on collecting in the author's twenties and thirties.
A new addition to the collection from January 2016, documented with the usual mix of photography and childhood-toy nostalgia.
Holiday recap from December 2015 covering Christmas gifts, Star Wars Episode VII chatter, and the Town of Exmore Christmas Parade.
A November 2013 review of an affordable knockoff building set, set alongside the author's decades-long love of Lego and Christmas-movie building marathons.
July 2013 entry on a bounty hunter figure acquired via trade with LeAnn of Retro Toy Safari, as the Star Wars Power of the Force 2 collection grows.
August 2013 tasting notes on a childhood favourite cereal, plus reflections on how many cereals have changed over the years.
A June 2013 League of Extraordinary Bloggers prompt on summer memories, fishing on the Chesapeake Bay, and learning the water from a 16-foot wooden scow.
A STEIDLE stroke limiter controls how far a reciprocating pump moves on each working cycle. On models fitted with the device, shortening that travel reduces lubricant delivered per stroke; allowing more travel increases permitted volume. It controls output, not pressure. Because arrangements and adjustment directions differ across STEIDLE pump families, the pump’s model number and operating manual should guide the physical procedure.
Before changing the setting, establish the required output in metric units, isolate the pump, relieve system pressure and measure actual delivery. This prevents a plausible setting from masking a blocked nozzle, incorrect pipework or excessive downstream restriction. The lubricant and machine builder’s cycle rate determine the final dose, not the limiter alone. The site also carries hobby material, including its stunt workshop notes, but those pages are not a substitute for STEIDLE operating documentation.
Locate the model, serial number and specification plate on the pump. Record the lubricant, maximum working pressure and output rating, which may be given in cubic centimetres per stroke, litres per minute or another unit. Older manuals sometimes use “cc”, equivalent to cm³. Confirm that the model actually has a mechanical stroke limiter; some pneumatic and electric units use other control methods.
Define the target as an amount per cycle and the machine’s cycle frequency. If a progressive distributor supplies several points, the required quantity may be specified for each lubrication point and then divided across the distributor’s outlets. Keep that target separate from line pressure, which is governed by viscosity, pipe resistance, nozzle size and the machine builder’s design.
Do not copy a limiter position from another STEIDLE pump. Two models with the same advertised flow may use different linkages or adjustment travel. If the manual is unavailable, supply the model and serial details so the correct procedure, adjustment range or spare part can be identified before anyone removes a cover or changes the setting.
Isolate electrical power, shut off and lock out pneumatic supply, and disconnect the drive where applicable. Relieve pressure using the method in the manual, including any accumulator or trapped oil downstream. Wear suitable eye protection and gloves, place absorbent material beneath unions and keep oily components away from ignition sources. Do not loosen a fitting that may still contain pressurised lubricant.
For a dependable test, route the outlet into a clean graduated container with enough capacity. A measuring cylinder works when the volume is clearly visible; for small outputs, collect several strokes and calculate the average. Record the liquid, test temperature and whether the pump is working against normal backpressure. Clean the strainer and confirm that the nozzle is not restricted before blaming the limiter.
Allow for Australian supply conditions when obtaining replacement parts through the Shenzhen office. Import entries incur GST and may attract customs duty, with the classification and rate determined for the particular pump or component; a customs broker can establish the correct treatment. For urgent maintenance in Melbourne, Sydney, Brisbane or Perth, ask whether suitable stock is held locally or must be freighted, since transit time can outweigh the purchase price.
Mark the current locknut and adjuster positions with a paint pen before moving anything. Release the retaining nut only where the manual identifies one, then turn or slide the adjusting element in small increments. Some mechanisms reduce travel as the adjuster moves inward, while others work oppositely; never assume clockwise means more output. Stop before the mechanism becomes stiff, and do not force the linkage or alter internal pump geometry.
Restore the retaining nut as specified and run a measured test. If the collected volume is V millilitres over n strokes, average output is V ÷ n millilitres per stroke. Repeat the test to check repeatability, then run the pump at normal operating pressure for final verification. Reconnect and purge the downstream line only after the isolated measurement is satisfactory, watching for air, leakage and unstable discharge.
| Limiter setting | Expected effect | Best application | What to confirm |
|---|---|---|---|
| Below the normal setting | Smaller working stroke and lower output per cycle | Fine metering or reduced lubricant consumption | The required dose still reaches every point |
| Factory or specified baseline | Rated stroke under the manufacturer’s conditions | Normal lubrication | Measured output matches the rating at working pressure |
| Toward maximum travel | Greater permitted output per cycle | Higher demand or restoring a worn setting | Pressure and system flow remain within limits |
The specified baseline is the appropriate starting point unless the machine’s lubrication calculation requires otherwise. Maximum travel is not automatically best: it can overload a distributor, shorten nozzle life or raise pressure beyond the pipework’s rating.
Calculate effective flow after measuring output per stroke. A pump delivering 0.5 mL per stroke at ten strokes per minute supplies 5 mL per minute, or 0.005 L per minute. This assumes the measured value holds at operating pressure and the controller continues to command the stated cycle rate. Changing a variable-speed drive, dwell time or number of distributor cycles changes total output independently of the limiter.
Check every part of the system rather than relying on the pump setting alone. A partly blocked nozzle, incorrect distributor setting, failed hose or programmed pause can produce uneven lubrication. Adjust branch outlets only to their specified values, and do not drill a nozzle or throttle the outlet to imitate reduced pump output. Confirm that the machine receives lubricant during startup, coast-down and emergency-stop phases.
Local conditions make this verification especially valuable. Food-processing plants around Melbourne and Brisbane may require documented food-grade lubricants and cleanable equipment, while mining and heavy-transport operations around Perth and regional WA often face contamination, long resupply routes and severe downtime costs. Local distributors can benchmark a measured setting against field experience, but the machine builder’s lubrication plan and pump manual remain the controlling references.
A frequent error is to change the limiter while the line remains pressurised. Another is to treat visible pump movement as proof of delivery: the pump may be cycling against a blockage, with lubricant bypassing an internal seal or never reaching the intended point. Begin with an isolated, measured test and compare the result with the pump’s published rating.
Do not use air pressure as an improvised substitute for mechanical adjustment. On a pneumatic STEIDLE pump, regulator pressure, exhaust back-pressure and flow restrictions affect delivery, and the manufacturer may prescribe a different method or prohibit changing a safety-related component. On powered units, alter cycle frequency only through the approved controller or drive settings; arbitrary speed changes can invalidate pump limits and machine calculations.
Record the final limiter position, test volume, number of strokes, lubricant, temperature and backpressure in the maintenance file. Note that the pump was checked under load, since clean, unloaded flow can differ from delivery to a hot machine. If output stays inconsistent after cleaning and adjustment, inspect valves, seals and worn components, then obtain model-specific service guidance rather than continuing to turn the adjuster.
To obtain the correct setting, spare part or availability information, send the Shenzhen office the pump model, serial number, lubricant type, current measured output and required target flow. Where possible, attach photographs of the identification plate and limiter so the relevant STEIDLE manual can be matched before work begins.
Request pricing and dispatch details with the inquiry, including stock location, freight options and customs documentation required for import into Australia. Schedule a controlled maintenance window for measurement, adjustment and verification, and ask the Shenzhen team to confirm the manual, current availability and delivery arrangements before the pump returns to service.
Star Wars Power of the Force 2 figures, Lego and knockoff building block reviews, and trades with fellow collectors.
Read toy posts →Weekly snack food and restaurant spotlights, from Hostess Fruit Pies to Froot Loops Treasures and beyond.
Read food posts →Summer vacations, fishing on the Chesapeake Bay, local community events, and other personal reflections.
Read life posts →